Evaporative Swamp Cooler Thermostats

Visit the Order Info Page to Order!
Email For Special Quote on Very Large Quantities

* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders

Installation Instructions Shipped With All Thermostats
Free shipping
Free Shipping on all Thermostats

P/N 7617 Cooler Controller ™

2 Speed 1/3 HP to 1 HP 115/230 Volt
Automatically Controls the operation of an Evaporative Cooler

P/N 7619 Cooler Thermostat
$69
Includes Free Shipping

Automatically controls the operation of the evaporative cooler.
LCD digital temperature readout with electronic temperature sensor circuitry.
Constant room temperature displayed.
Easy single touch temperature adjustment.
Case door covers operating controls
Four-minute blower start delay when using pump feature for pad wetting.
Installs in standard depth 2 x 4 single gang electrical box.

UL Listed, 1 HP, 115 VAC, 60Hz

 

 

 

P/N 7619 Cooler Thermostat

Thermostat Wall Plate
P/N 7616
Wall Plate
Adapts Digital Thermostat Controller to a 2 gang electrical junction box

$6

Installation Instructions Shipped With All Thermostats

P/N 7625 EZIStat Controller ™

2 Speed 1/3 HP to 1 HP 115 Volt and 230 Volt
Automatically Adjusts Motor Speed
Also Has Manual Control for 2 / 4 / 8 Hour Timer Mode

P/N 7621 EZIStat

No Longer Available

Automatically adjusts from High to Low speed
as the temperature approaches set point.
Optional manual control for cool (pump) and fan only
2 / 4 / 8 hour timer mode
Automatic start and stop – in “Cool” Mode only
Simple 5 wire interface
Installs in standard 2 x 4 single gang electrical box

P/N 7621 EZIStat

Thermostat Wall Plate
P/N 7616
Wall Plate
Adapts Digital Thermostat Controller to a 2 gang electrical junction box
$6

Installation Instructions Shipped With All Thermostats

P/N 7620 SELECT-A-STAT Cooler Controller ™

2 Speed 1/3 HP to 3/4 HP 115 Volt
Bimetal temperature sensing with unique heat anticipator
Line voltage thermostat & controller
Includes switches to control pump & 2-speed motor (15 amps)

P/N 7620 Select-A-Stat
 NO LONGER AVAILABLE
Automatic start & stop for temperature control
Includes separate control of high and low-speed blower motor and control of pump
Bimetallic sensing element
Includes thermostat, motor switch, pump switch, leads and installation wiring diagram
Installs easily with 4 lead wires and ground terminal
Designed for installation in single gang or double gang electrical boxes (not included)
Rated 15 amps at 115 volts VAC. UL Listed

Installation Instructions Shipped With All Thermostats

Replacement Window Cooler Grills and Covers

Visit the Order Info Page to Order!
Email For Special Quote on Very Large Quantities

* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders

Replacement Window Cooler Grills For Champion/Marquis Brands Only
The Grills & Winterizing Covers Below Are Designed to Fit Champion Brand
Window Coolers Only
Check dimensions of grills & covers shown above

We do not Guarantee they will fit any other cooler brands

Grills & Covers are NOT SUBJECT FOR RETURN

New Champion Window Cooler Grill
Part No. 110839-1
Fits Newer Model Champion Window Coolers
Made After 2003

Old Champion Window Cooler Grill
Part No. 310833-001
Fits Older Model Champion Window Coolers
Made Before 2004

NO LONGER AVAILABLE

Part No. 110839-1
$69

Grill Dimensions
21 1/2″ x 13 7/8″

Part No. PSA-10833-002
WITH SWITCH & KNOB

NO LONGER AVAILABLE

Grill Dimensions
25″ x 12 1/4″

Winterizing Window Cooler Ridgid Plastic Grill Covers For Champion/Marquis Brand Only

Champion WCM28 Grill
Part No. 310834-101

Fits Older Model Champion WC28 or WCM28
(switch in the center)

NO LONGER AVAILABLE

Champion Window Cooler Grill Cover
Part No. 110829
$56  Free Shipping
Only Fits Champion Model Window Coolers Only
Made After 2003

DOES NOT FIT
WC 28 OR WCM 28 COOLERS

Part No. 310834-101

 NO LONGER AVAILABLE
Grill Dimensions
21 1/2″ x 11″

Part No. 110829
$56

Includes Free Shipping
Fits Grill Measurement of
21 1/2″ x 13 7/8″
The Above Grills & Winterizing Covers Are Designed to Fit Champion Brand
Window Coolers Only
Check dimensions of grills & covers shown above

We do not Guarantee they will fit any other cooler brands

Grills & Covers are NOT SUBJECT FOR RETURN

* Please Note, There Is A $25 Minimum Charge For Cooler Parts Orders

Ceiling Diffusers Wall Grills

Visit the Order Info Page to Order!
Email For Special Quote on Very Large Quantities

* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders

#7637 Plastic Ceiling Diffuser
Diffuses Air 4 Ways or 6 Ways

With 14 Adjustable Louvers
White High Impact Plastic
Will Not Rust, Corrode or Stain

Overall Size of Grille is

22 1/2″ x 22 1/2″ x 3 1/8″ Depth

For Duct Openings
16″ x 16″ up to 20″ x 20″

Plastic Ceiling Diffuser
#7637 Plastic Ceiling Diffuser

$49 Plus $17.50 UPS shipping
$66.50 Total

Plastic Side Wall Register
#7700 Series Plastic Registers

have been DISCONTINUED.

7791
6 x 6
2 Way
 
7792
8 x 6
2 Way
 
7794
12 x 6
3 Way
 
7795
14 x 6
3 Way
 
7796
16 x 6
3 Way
 
7797
20 x 6
3 Way
 
7799
14 x 8
3 Way
 

 

Ceiling Grill
#7700 Series Plastic Register
Ceiling

7788
8 x 8
4 Way
 

 

See Description & Features Below

~ 7700 Series Plastic Registers~

Are No Longer Available

As of 8/2/11 these registers are no longer available.

#7700 Series Plastic Side Wall Registers

And

#7700 Series Plastic Ceiling Registers

Sizes shown are width and height for inside duct hole

Add 2″ to width and height for outside dimensions

Plastic cooler, heating, and air conditioning vents are economical and practical

Will not rust

Cleans with soap and water

Pull to open, push to close for damper operation

Built in opposed blade damper effect for system balancing

Attractive brush finished trim that can be painted to match decor

Easy to install, mounting screws and installation instructions included

Evaporative Swamp Cooler Wall Switches

Visit the Order Info Page to Order!
Email For Special Quote on Very Large Quantities
* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders
RSK 2 Wall Switch Wiring Diagram
RSK 2 Wiring Diagram

Click Here For Window Cooler Grill Switches

 

RSK 2 Rotary Wall Switch
For Side Draft And
Down Draft Coolers

(see wiring diagram on left)

Cooler Wall switch
RSK 2
$25

Note!
$25 Minimum Charge For Parts OrdersClick Here For Window Cooler Grill Switches

WARNING:
HOUSE VOLTAGE CAN BE LETHAL

1. Turn off power before installing the switch. The installer of this switch must be technically qualified for this type of installation. A qualified electrician should check all wiring and circuit breakers and be sure that the cooler installation is effectively grounded.

2. Refer to evaporative cooler installation instructions and all applicable electrical codes for correct installation of the evaporative cooler, switch and wall switch box, correct wiring procedures, and effective grounding.

3. Motor and pump voltage and amperage must not exceed switch specifications. This switch is recommended for 120-volt applications only.

4. This diagram is a basic schematic and is not intended to represent all methods of installation because of various cord, plug, and pump configurations. See evaporative cooler installation instructions and motor and pump instructions for proper motor and pump wiring. Be sure motor, pump, and cooler are properly grounded. Color coded wires must not be interchanged or interconnected with each other.

5. CAUTION: Turn the switch to “OFF” position before turning power on.

Evaporative Window Cooler Switches

Visit the Order Info Page to Order!
Email For Special Quote on Very Large Quantities
* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders

Click Here For Cooler Wall Switches

Typical Wiring For
PART NUMBER 110425
FOR ALL
Champion Brand Window Cooler Switcheswiring diagram #1

Champion Window Model Wiring Diagram

Typical Wiring For

OTHER Brands Window Cooler Switches

(NOT CHAMPION BRAND)
P/N 7212 & P/N 7225

wiring diagram #2
Other Brand Window Switch Wiring

Wiring Diagrams Sent With All Switches

See Terminal Connections on Back Side
of Switches Shown on The Right
to Determine The Switch P/N
You Need

wiring diagram #3
P/N 7221 Wiring Diagram
SPECIFY P/N 110425 SWITCH
FOR ALL
CHAMPION BRAND
WINDOW MODEL COOLERS

Click Here For Wall Switches

WARNING:
HOUSE VOLTAGE CAN BE LETHAL

1. Turn off power before installing the switch. The installer of this switch must be technically qualified for this type of installation. A qualified electrician should check all wiring and circuit breakers and be sure that the cooler installation is effectively grounded.

2. Refer to evaporative cooler installation instructions and all applicable electrical codes for correct installation of the evaporative cooler, switch and wall switch box, correct wiring procedures, and effective grounding.

3. Motor and pump voltage and amperage must not exceed switch specifications. This switch is recommended for 120-volt applications only.

4. This diagram is a basic schematic and is not intended to represent all methods of installation because of various cord, plug, and pump configurations. See evaporative cooler installation instructions and motor and pump instructions for proper motor and pump wiring. Be sure motor, pump, and cooler are properly grounded. Color coded wires must not be interchanged or interconnected with each other.

5. CAUTION: Turn the switch to “OFF” position before turning power on.

Click Here For Wall Switches

 

Window Cooler Switches
Below

Chamjpion Cooler Short Stem Switch
P/N 110425
Fits Champion
Window Coolers Only
(see wiring diagram #1 on left)
$24
Cooler Switch Knobs Below

P/N 110839-006
Newer Models
Left Knob Image
Above
$8
P/N 110836
Older Models
Right Knob Image
Above
DISCONTINUED

See Below For Other Cooler Brands Switches

All Other Brands
Window Cooler Switches
Below
(see wiring diagram #2 on left)
Short & Long Stem Switch

P/N 7212
DISCONTINUED
(P2-3006-1)
Short Stem
Switch
No Longer Available 

P/N 7225
DISCONTINUED
(P2-3006-3)
Long Stem
Switch
No Longer Available 

Long Stem Switch
P/N 7271
Old
(P2-171)
DISCONTINUED
Long Stem
Switch
No Longer Available

Window Switch Knob
Switch Knob
Front View
$7

P/N 7450
Short Shank Knob
P/N 7481
Long Shank Knob
Window Switch Knob -side view
Window Switch Knob -side view
Side View of Knob

Note!
$25 Minimum Charge Plus S/H
For Parts Orders

POWER CLEAN KIT ®

Power Clean Purge Pump

P/N 1540 Power Clean Kit
115 VOLT
$83
Includes S/HP/N 1542 Power Clean Kit
230 VOLT
$87
Includes S/H

Free Shipping
UPS Regular Ground
AUTOMATICALLY FLUSHES YOUR COOLER
5 Minutes After Every 8 Hours of Cooler Pump Use
MINUTES TO INSTALL

POWER-CLEAN® Kit includes…

Purge Pump
Mounting Bracket
Mesh pump screen
30 inches of 1/2 inch I.D. vinyl drain hose
Drain hose to overflow pipe adapter
Installation instructions

Visit the Order Info Page to Order!
Email For Special Quote on Very Large Quantities

Click Here To See Installation InstructionsTimer activates Power-Clean®
For 5 Minutes Every 8 Hours

Does Not Replace Existing Water Pump
Does Not Replace Existing
Cooler Pump

Power Clean Special Plug
Power-Clean Plugs Into Receptacle
Existing Cooler Pump
Plugs Into The Back Of The
Power-Clean Plug

Saves water and money
Freshens air
Prevents mineral build-up
Reduces maintenance
Pads last longer
Fits all coolers

 

Power Clean Installation Instructions

CAUTION:

  • Disconnect electrical power to cooler before installing your POWER-CLEAN ® system or servicing cooler
  • Installation must comply with cooler manufacturer’s specifications and all applicable building and electrical codes. For safety against electrical shock, cooler cabinet, blower motor, pump(s) and switch(es) must all be properly grounded.

INSTALLATION PROCEDURE:

  • Disconnect Electricity to Evaporative Cooler.
  • Unplug Pad Pump
  • Place Pump Screen Onto POWER-CLEAN ®
  • Pump.Mount POWER-CLEAN ® Pump Inside Cooler. Secure pump to blower housing with mounting bracket.
  • Install Hose Adapter Into Overflow Pipe. Place proper end of hose adapter into overflow pipe. See markings on hose adapter.
  • Attach 1/2″ Hose From POWER-CLEAN ®
  • Pump To Hose Adapter. Securely attach hose onto pump. Connect other end of hose onto hose adapter. Avoid kinking hose — cut hose if deemed necessary.
  • Plug-In POWER-CLEAN ® Pump. Note the specially integrated plug and receptacle on the POWER-CLEAN ® pump cordset.
  • Plug-In Pad Pump. Plug your pad pump into the specialPOWER-CLEAN ® pump receptacle.
  • Connect Piping To Remove Cooler Water. Do not allow cooler water to run onto the roof. Connect garden hose, or 3/4″ PVC piping from the underside of the cooler drain to an appropriate drain site on the ground. Use of 45-degree elbows instead of 90-degree elbows is recommended. This will prevent unsightly roof stains as well as potentially damaging effects to roof shingles.
  • Reconnect Electricity to Evaporative Cooler.
  • OPERATING:Your POWER-CLEAN ® system automatically removes the water in your cooler once *every 8 hours that the cooler pad pump is “ON”. This periodic draining replaces the ‘hard’ water that naturally develops in the cooler with clean, fresh water in a consistent manner. The result is decreased scale build-up, longer pad life, less cooler maintenance and lower water usage (compared to a standard bleed-off system).

IMPORTANT:

  • POWER-CLEAN ® drains the water depth to less than 1/2 inch.
  • During the POWER-CLEAN ® draining cycle, both purge and pad pumps are “on”.

CONTENTS:

1 POWER-CLEAN ® Purge Pump

1 Mounting Bracket

1 Pump Screen

*1 Pump Hose (1/2″ I.D., 30 inches long)

1 Hose Adapter (Purge Pump Hose to Overflow Pipe)

Note for Tucson, Arizona Area Installations:

Certain building/electrical codes require the use of a “P-26 Fuse Box”, such as the G.E. Model No. T-U261F rainproof power outlet fuse box when wiring a cooler.

When using this fuse box, a fuse rated at 1.6 Amp might be required for proper operation of the POWER-CLEAN ® system vs. the smaller 1.25 Amp fuse. These fuses are a type S time delay and must be used ahead of the cooler pump and POWER-CLEAN ® system.


LIMITED WARRANTY:

  1. Purge Pump is warranted under normal use and recommended maintenance for 2 years from date of sale to user. In event of defect or failure, replacement is made through your authorized dealer or retailer.
  2. Reason for replacement, purchase date, and sales receipt mustaccompany pump returned for replacement.
  3. Warranty is void if pump has been abused, altered, water damaged or improperly installed.
  4. We do not pay the cost of a service call at the site of installation to diagnose cause of trouble, or the cost of labor or transportation to replace a defective pump.
  5. We are not responsible for any incidental or consequential damage resulting from any malfunction unless required to do so by state law.

Evaportative Swamp Cooler Pumps and Float Valve Assemblies

We Stock Residential & Industrial
Evaporative Swamp Cooler Pumps
& Brass Float Valve Assemblies

UL 6500

Residential Coolers


UL 11000
UL 21000

Industrial Coolers

NOR 120 Marquis Pump
NOR 120
Marquis Cooler Pump
DISCONTINUED
NOT LONGER AVAILABLE


1/4″ Brass Float Valve
1/4″ Compression Connection Only
Fits All Residential Coolers

We Recommend Brass Body Float Valves
NOT PLASTIC BODY
Brass Body is More Durable

3/8″ Brass Float Valve
For Large Industrial Coolers
Specify Iron Pipe or Compression Connection
P/N 4178   For   3/8″        Iron Pipe Connection
P/N 4164   For   3/8″       Compression Connection
Model No.
Description
Pump
Cost
Brass Float Valve Assembly
UL 6500
115 Volt
For All Residential Model Coolers
$ 35
+$12 S/H
1/4″
$9
UL 11000
115 Volt
For Up To 11,000 CFM
$ 39
+$12 S/H
3/8″
$15
UL 11000
230 Volt
For Up To 11,000 CFM
$ 41
+$12 S/H
Specify
P/N 4178 3/8″
Iron Pipe Connection
UL 21000
115 Volt
For Up To 21,000 CFM
$ 47
+$13 S/H
P/N 4164 3/8″   Compression Connection
UL 21000
230 Volt
For Up To 21,000 CFM
$ 50
+$13 S/H
Specify Voltage For
Pump Orders
* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders
Click Here For Ordering Information

Evaporative Swamp Cooler Motors, Pulleys & V-Belts

* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders
Cooler Motors
Copper Winding
We Stock Residential & Industrial
Evaporative Swamp Cooler MotorsResidential Motor Pricing Below

E-mail
For Industrial Cooler
Motor Pricing

V-Belts
V-Belts
Motor Pulleys
Cooler Motors
S/H via UPS regular ground
S/H Not Included in Part Price
Two Speed
115 Volt – 60 cyc
Cost
1/2″ Cooler V-Belts
Motor Pulleys
Cost
1/3 HP
$ 89
+$17 S/H

1/2″ V-Belts 45″ – 69″
$10

3 1/4 x 1/2
Adjustable
$ 13
1/2 HP
$ 105
+$17 S/H
Find V-Belt Size For
Champion Residential Coolers
On Following Spec Pages 
3 1/2 x 1/2
Adjustable
$ 13
3/4 HP
$133
+$17 S/H
Champion Window Specs
Example 4L450 = 45″ V-Belt
2 1/2 x 1/2
Fixed
$10
1 HP
$205
+$17 S/H
Champion Side Draft Specs
Example 4L560 = 56″ V-Belt
2 3/4 x 1/2
Fixed
$10
Motors are 1725 rpm
(Standard for Evap Coolers)
Champion Down Draft Specs
Example 4L690 = 69″ V-Belt
3 x 1/2
Fixed
$10
* Please Note, There Is A $25 Minimum Charge PLUS S/H For Cooler Parts Orders

AeroCool Cooler Pads

RIGID MEDIA COOLING PADS

THE ULTIMATE COOLING MEDIA
FOR SINGLE INLET COOLERS
Long Life – High Air Velocity – Energy Efficient
Consistent Performance50% heavier paper holds more water and lasts longer
Independent lab and field tests verify the highest efficiency
Fast wet-outEngineered for optimal performance and longevity…Cellulose base impregnated with plastic resins and anti-rot agents…Durable and easy to install.
Celdek Pads
Rigid Cooling Media Pad
Pad is not one piece
Comes in Sections
2 – 4 sections per set
to make correct width8″ & 12″ Thick Pads
The Most Efficient type of
Cooler Pad Made
Visit the Order Info Page to Order!
Email For Special Quote on Very Large Quantities

Other Sizes Available
Including 12″ Thickness

Free Shipping/Handling included in Price

AeroCool Pads
Click Here For:
Installation Instructions

8″ Thick
Pad

P/N 3437
40 x 23 x 8
AeroCool 4800

$128 Total Cost

Free Shipping

8″ Thick
Pad
P/N 3439
40 x 30 x 8
AeroCool 6800
$158 Total Cost

Free Shipping

AeroCool Window Cooler Model
BW 5500 Brisa

 Note:
New Rigid Cooling Media Pad type pads will emit a slight odor when first installed
Click Here To See Why