Dearborn Heaters are no Longer Made
Archives
Reznor Gas Fired Unit Heaters
Ceiling Hung Vented Gas Unit Heaters
Reznor Unit Heater Standard Features
Above 6,000′ requires special ordered pressure switch
|
Can be Vented Horizontal or Vertical Fresh Air For Combustion That Fails Within Five Years No One Else Offers This Warranty To Our Knowledge www.rezspec.com |
Freight Cost Varies Depending on Your Location
Check out the Order Information page for how to order.
We Do Not Ship Reznor Unit Heaters via UPS
These Heaters Are Palletized To Prevent Damage And Must Be Shipped via Common Carrier |
Reznor Model UDAP Unit Heaters
|
||||
Models Shown Here Are Our Normally Stocked Items24 Volt Thermostat Not Included |
||||
Shipping Not Included |
||||
Specifications for Reznor UDAP Unit Heaters |
Model |
BTU Input |
Thermal Efficiency |
Size |
Weight |
||||
A
Height |
B
Width |
C
Heater Depth |
D
Total Depth |
|||||
12 1/8
|
26 5/8
|
21 9/16
|
26
|
|||||
15 1/8
|
26 5/8
|
21 9/16
|
27
|
74 lbs
|
||||
15 1/8
|
26 5/8
|
21 9/16
|
27 5/8
|
|||||
23 1/8
|
26 5/8
|
21 9/16
|
28 5/8
|
|||||
UDAP 125
|
125,000
|
83%
|
23 1/8
|
26 5/8
|
21 9/16
|
29 3/8
|
4″
|
123 lbs
|
20 1/8
|
38 3/16
|
35 3/8
|
42
|
|||||
20 1/8
|
38 3/16
|
35 3/8
|
42
|
|||||
20 1/8
|
38 3/16
|
35 3/8
|
42
|
|||||
26 1/8
|
38 3/16
|
35 3/8
|
42
|
Reznor V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for residential application. All sizes are approved for commercial/industrial installations. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association(CSA).
Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish, unique REZNOR mitered corner and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a”G” terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection.
The preeminent new internal feature is the T-CORE2 heat exchanger and single burner combustion system. Other standard features include a single-stage gas valve, multi-try direct spark ignition with 100% lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high-temperature limit control. Sizes 30-125 also include a flame rollout safety switch. The operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions.
Click Below For More Information at Reznor Web Site
www.rezspec.com
Cozy Gas Floor Furnaces Typical Venting Illustration
Cozy Gas Floor Furnaces
Typical Venting Illustration
Illustration Below & Gas Piping Information
|
Cozy Gas Floor Furnaces
The Cozy Challenger Floor Furnace provides warm even heat
through the natural convection of circulating warm air |
|||
Cozy Floor Furnace Features
|
Click Here For Floor Furnace
|
||
The Safety Limit Control on a Cozy Floor Furnace Setting No. 1 Setting No. 2
|
Freight Cost Varies Depending on Your Location |
~ PLEASE CONTACT US FOR ANY AVAILABLE DISCOUNTS FOR ONE OR MORE UNITS ~
|
Cozy Floor FurnacesModels Shown Here Are Our Normally Stocked Items |
|||
Wall Thermostat Included With Heater
|
|||
Ship Wgt
|
|||
108#
|
$ 1,046
|
||
126#
|
$ 1,203
|
||
152#
|
$ 1,360
|
||
181#
|
Discontinued | ||
All Models Stocked in Natural Gas Only
For Propane Conversion Kit Add: $59 This Model is a Vented Heater Venting Material Is Not Included in Pricing |
Specifications |
||||
Sunstar FAQ
Frequently Asked Questions
- What is an ODS and how does it work? The ODS is an oxygen detection safety pilot system. It is designed to shut off the gas supply to the heater if the oxygen content in the room drops to 18% from a normal 21%+. In this event, the pilot flame actually lifts off the thermocouple cooling it down and causing the gas valve to close and the heater to shut off. Also, each ODS has a tamper-resistant pilot orifice assembly, so do not try to drill or clean out the ODS pilot with a hard object as you will damage it. Follow the cleaning instructions located below.
- How do I clean the ODS pilot assembly? If your pilot will not stay lit, try cleaning it. Use a can of compressed air, such as is used to clean a computer, to blow dust out of the pilot assembly. Sometimes just blowing air back through the pilot will get rid of the dirt.If that fails, turn off the gas supply to the heater. As indicated in Figure 5 below grab nut A with an open -end wrench and loosen nut B from the pilot tubing with another small adjustable wrench. Blow air pressure through the holes as indicated. This should blow out any foreign materials. To reassemble, tighten nut B by grabbing nut A with the open-end wrench. WARNING: When the heater is reassembled, always check for gas leaks. Apply a soap and water solution to all joints and watch for bubbles to check for gas leaks. Never use any open flame to check for gas leaks.
If that fails, you need to remove the orifice from the pilot burner cartridge using your wrenches to unscrew the orifice (Item A) and blow air through the pilot burner as shown in Figure 5. If the pilot burner remains blocked you will need to use a soft brush (pipe cleaner will also work) to dislodge a spider web or other obstruction. To prevent damage to this assembly, follow the instructions below for disassembly and assembly of the ODS for cleaning.
WARNING: Never use needles, wires, or similar cylindrical objects to clean the pilot orifice. This will only damage the calibrated pilot orifice (about the size of the head of a pin) which controls the pilot gas flow. Simple rinsing with water and blowing air over it should clean the orifice. - How does this SunStar Corcho Model CK18 heater work again? (Applies to Manual ONLY) It’s slightly different than some 3-plaque heaters you may have seen previously. Instead of turning on the pilot and then one, two, and three plaques, the SunStar Corcho Model CK18 uses just two burner chambers and operates first on the single plaque burner. After the single plaque comes on, the double plaque is turned on giving you three full plaques of operation. If only two plaques are needed, then the double plaque burner may shut off leaving just one plaque burning.
- Can a SunStar Corcho heater be converted to Natural or Propane Gas? No, each heater is specifically designed to work on either Natural Gas or Propane Gas. Each heater is certified only for use with the type of gas indicated on the heater nameplate (data plate). It is not designed for use with other gasses and is not convertible to use with other gasses.
- Why doesn’t it need electricity? Each SunStar Corcho heater is equipped with a thermocouple incorporated in the ODS assembly. This is also the flame failure safety system. The heat from the pilot light warms the thermocouple and the dissimilar metals in the thermocouple react to the heat from the pilot flame and create a small amount of electricity (e.g. millivolts of electricity). This electricity from the heat is then used to energize a magnet in the gas valve to open it against the tension created by a spring in the gas valve. This allows gas to go to the burners. When the pilot flame is extinguished and is no longer generating heat on the thermocouple and, thereby, millivolts of electricity, the magnet de-energizes and the spring shuts the valve off. This is designed to turn off all the gas to the burner and pilot system. The use of this safety system and the gas fuel are the reasons that no electricity is needed to operate a SunStar Corcho heater. This product will still provide heat to your home even during power outages.
- Can these heaters be installed in bedrooms or bathrooms? Only the model CK-6 (rated at 6,000 Btu’s) can be installed in a bathroom. Both the CK-6 and the CK-10 (rated at 9,500 Btu’s) can be installed in bedrooms. All other models are too big. The National Fuel Gas Code (NFPA 54) permits wall mounted installation of vent-free gas heaters of 10,000 Btu’s or less in bedrooms and 6,000 Btu’s or less in bathrooms. Please check with your gas supplier to determine if the installation of these heaters in bedrooms and bathrooms are permissible by your state and local codes.
- Can this heater be installed in mobile homes? Yes, this heater may be installed in what’s termed “aftermarket” manufactured (mobile) homes where it is not prohibited by state or local codes. An “aftermarket” mobile home is defined as any type of mobile home that has already been sold to an end user or homeowner. It cannot be installed in a new mobile home on the dealer’s lot before it has been sold, but it can be installed in any mobile home after it has been sold (e.g. aftermarket). When installing this heater in a mobile home, the same safety rules of confined and unconfined spaces and clearance to combustible materials should be followed.
SunStar Corcho Heater Factory Warranty
10 year Limited Ten-Year Warranty
SunStar Heating Products, Inc. (SunStar) warrants SunStar Corcho gas heaters to be free from defects in workmanship and materials present at the time of shipment from the factory for a period of ten (10) years from the date of purchase by the original purchaser. The purchaser’s sole remedy under this limited warranty is as follows: If a purchaser discovers and reports to SunStar or the SunStar Corcho dealer/distributor a defect covered under this warranty within ninety (90) days from the date of purchase, SunStar or the SunStar Corcho dealer/distributor will, at the purchaser’s option and upon proof of purchase (including model and serial number) repair or replace the defective unit. If a purchaser discovers and reports to SunStar or the SunStar Corcho dealer/distributor a defect covered under this warranty more than ninety (90) days but less than three (3) years from the date of purchase, SunStar or the SunStar Corcho dealer/distributor will provide the purchaser at no charge and upon proof of purchase (including model and serial number) with parts necessary to repair the unit; or, if the purchaser first notifies and receives approval from and thereafter promptly returns (at the purchasers’ expense) the defective unit to SunStar’s SunStar Corcho Service Center (see phone contact below) SunStar will repair or replace, at SunStar’s option, the defective unit and return it to purchaser at no additional charge. If a purchaser discovers and reports to SunStar or the SunStar Corcho dealer/distributor a defect covered under this warranty more than three (3) years but less than ten (10) years from the date of purchase, SunStar shall, upon written notice to SunStar, (including model and serial number) provide the purchaser with parts necessary to repair the unit at no additional charge; provided the purchaser returns any defective parts needing replacement to SunStar’s SunStar Corcho Service Center (as provided for below) at the purchaser’s expense.
Duties Of The Owner
The heating appliance must be installed by a qualified installer and operated in accordance with the written instructions furnished with the appliance. Ready access to the appliance for service is the responsibility of the owner. Travel, diagnostic cost, service labor, labor to repair the defective appliance and freight charges on warranty parts to the factory will be the responsibility of the owner after the first 90 days of ownership have expired. A bill of sale, canceled check, or payment record should be kept to verify purchase date and remaining warranty period. Original carton should be kept for warranty return of the unit.
What Is Not Covered
This warranty does not imply or assume responsibility for consequential damages that may result from the use, misuse or improper installation of this heating appliance and in no event shall SunStar be responsible for such damages. This warranty does not cover claims, which do not involve defective workmanship or materials.
Your Rights Under State Law
This warranty gives you specific legal rights and you may also have other rights, which may vary, from state to state.
How To Get Service
All parts or products returned due to defects must be shipped prepaid to an Authorized SunStar Corcho Service Center. Please contact your SunStar Corcho dealer for service details or to obtain return authorization. If, after contacting your SunStar Corcho dealer, service received has not been satisfactory, contact: SunStar Corcho Service Center, SunStar Heating Products, Inc., P.O. Box 36271, Charlotte, NC 28236 or call at (704) 372-3486.
SunStar Corcho Gas Infrared Heaters
SunStar Gas Infrared Heaters
Click Here For Our Shop & Construction Site InfraRed Heaters
Click Here For Patio InfraRed Heaters
The SunStar Corcho line has been designed with many options and features including:
|
|
Scroll for Specifications Frequently Asked Questions
Model SC 6
|
Model SC 10
|
Model SC 18
|
Model SC 30
|
|
Manual Only
|
Model SC 10 T
|
Model SC 18 T
|
Model SC 30 T
|
Manual
|
With Thermostat
|
Manual
|
With Thermostat
|
Manual
|
With Thermostat
|
Manual
|
With Thermostat
|
N/A
|
N/A
|
$230
|
$310
|
$257
|
$339
|
$340
|
$389
|
5 YEAR WARRANTY
When Placing An Order: Specify Type Gas To Be Used – Natural Gas or Propane
|
|||||||
Note: The suffix “T” is used to designate thermostatically-controlled models.
6,000 BTU Model – Manual Only Available |
Includes UPS Free Shipping to the 48 Inland States
We Confirm Your Total Cost On All Orders Prior To Shipping
Optional Accessories For SunStar Infrared Heaters
Optional Floor Base for Models CK6 & CK10
$36 No Optional Floor Base Needed for Models SC 18 & SC 30 |
Optional Blower Accessory For Models SC18& SC30
$89 Optional Blower Not Available For Models CK6 & CK10 |
Oxygen Depletion System automatically extinguishes flame and gas flow if oxygen drops to unsafe levelsTEN YEAR Limited Warranty See Actual Factory Warranty HerePUSHBUTTON IGNITER Effortless push-button spark pilot lighter Optional Automatic Thermostat Efficiency 99.9% Fuel efficient Optional Blower (Squirrel Cage Type)
|
* Because states, counties, and municipalities adopt various codes, please check with your installer or local code officials to assure the current code in the city where you plan to install permits vent-free gas appliances. While most states permit installation of vent-free gas heating appliances, a handful of states still prohibit residential use. Very often, that’s because a state’s building codes haven’t caught up with vent-free gas technology. * Several counties and municipalities in Colorado and Utah permit the product. Wisconsin restricts installation in homes built after 1980
|
Infrared Plaque Heaters Radiate Heat And “Warms like the Sun” Quickly Warms People & Objects Before Heating The Air |
ODS System Oxygen Depletion System Cuts Off Gas & Burner If Oxygen Falls Below Safe Levels Matchless Spark Ignition |
Specifications
|
SunStar Construction Heating Products
RCH series
Heavy Duty Infrared Heat SunStar’s infrared construction heaters provide exceptional on-the-job versatility. These tough, reliable and job proven heaters are packed with features for both economy and rugged endurance. Built with heavy gauge steel they are designed to withstand continuous seasonal use even in severe industrial and construction type environments.
|
RCH100-N9A (nat gas w/t-stat control)RCH100-L9A (LP gas w/t-stat control)Scroll Down for Specifications |
Typical ApplicationsConstruction Sites Workshops |
|
Features |
|
|
|
Specifications
|
SunStar Patio InfraRed Heaters
Click Here For Our Residential InfraRed Heaters
PH seriesEnjoy Your Outdoors Longer with a
|
|
Williams Chamberlain Direct Vent Gas Wall Furnace Rough In Dimensions
Rough In Dimensions & Recommended Clearances BelowUse Template Shipped With Heater To Cut Openings For Vent |
|
14036 Series
|
22036 & 30036 Series
|
|